Information
-
Users, for which the
customizer rights
parameter is activated receive the Problems in System Customizing dialog message.
-
In this dialog message, errors in the system customizing of customer specific objects (data items, exits, etc.) are pointed out. If erroneous changes to standard objects are made, these errors, except for few exceptions, are not listed (see table below).
-
The messages are listed below one another.
-
-
In the following table, the different error messages and their meaning are explained.
-
In case an error message that is displayed on your screen is not listed in this table, please contact PLANTA.
|
Message |
Explanation |
|---|---|
|
|
The DI Python ID must be unique in the data table.
|
|
|
Parallel data items ( SQL = 4 and same SQL ID ) must have the same DB pos.
|
|
|
Relation type = Relation
|
|
|
The Exit has not been customized properly. It neither has a fetch DI nor a fetch DI.
|
|
|
The Exit has not been customized properly. It neither has a source DI nor a fetch DI .
|
|
|
The Exit has not been customized correctly: The DB type of the source DI as well as the DB type of the primary key from the fetch data table do not match.
Note
|
|
|
The Exit has not been customized correctly: The DB type of the data item on which the exit is customized, as well as of the fetch DI do not match. |
|
|
The Exit has not been customized correctly: The data table of the DI on which the exit is stored does not correspond to the data table of the source DI . |
|
|
The exit of the DI could not be loaded for one of the reasons mentioned above.
|
|
|
An incarnation requires a sub DI with ID function as well as one with KO function .
|
|
|
The respective data item does not exist or is deactivated.
|
|
|
The respective data item does not exist or is deactivated.
|
|
|
The data item has a VR type but no value range .
|
|
|
DIs with class 13 must have DB type X.
|
|
|
The data table has no primary key.
|
|
|
It is a DI with SQL = 3 for which there is no SQL DI = 1 and identical SQL ID.
|
|
|
The DB pos. must be unique in each data table.
DIs with identical values in the SQL ID parameter and SQL = 4 present an exception. These data items may possess a double DB pos.
|
|
|
In DI Pos.OS , the wrong DB pos. of the first object protection field is specified.
|
|
|
This DI or data table only exists in PLANTA and not in the database or the UUID is missing in the PLANTA data table
Note
|
|
|
The field length stored in the database is incorrect. This message is also displayed for standard DIs.
|
|
|
In the DB, no field length is stored for the respective columns.
|