DT411 Data field
DI000213 DI
ID of the data item which is used for the data field
DI002060 Data item
Name of the data item which is used for the data field. This name is displayed in the modules as data field heading in case there is no entry in the DF heading parameter. If there is a deviating entry in the DF heading parameter, it will be used as data field heading in the modules.
DI000984 DT
Data table from which the data item of the data field stems
DI010200 DF heading
Here, you can define an individual heading for each data field of a data area. The entry defined here is displayed in the user view of the module instead of the name which is displayed in the data item. For buttons or context menu entries (DF behavior c... and m...), this entry is displayed instead of the module name of the module to be opened.
Notes
- If the data field heading for a particular field is not to be displayed in an area which is no form (Layout parameter = 0 or 1), you have to enter ASCII code 0160 to generate a non-breaking space. To do so, you have to press the ALT key while entering the 4 digits.
- In this field, variables(@D, @G and @(System variables) can be used, the values of which are read when the module is opened.
- Use a double @ to make sure that the variable (e.g. @D) is not read but an @ sign is actually output in the field. E.g.: If the heading contains @@D15, @D15 is displayed as text in the heading in the module.
DI041088 DF Python ID
Identifier of a data field. It is used in connection with Python to identify the data field.
Notes
- Names must be usable as Python literals. They must not contain any special characters, umlauts, spaces, etc.
- The DF python ID must be uniquely defined in the data area.
- Individual Python IDs must start with an L and the license number.
- Example: L011_request
- This value can also be preset on the data item in the DI Python ID data field.
- In this case, the preset Python ID and the "DI:" entry are displayed.
- If the Python ID in the DI is, e.g., "requested_start", "DI: requested_start" is written in the DF Python ID data field.
- The preset value can be overwritten. If this value is deleted, the preset from the data item is displayed again.
- In this case, the preset Python ID and the "DI:" entry are displayed.
- The Python IDs of default data fields cannot be changed.
DI000307 DF
ID of the data field
DI000203 Traffic light DI
Here, a traffic light DI is entered which serves to achieve a traffic light function (highlighting of a field depending on the stored values by the means of traffic lights).
Note
- The traffic light symbols overwrite the symbol stored in the Symbol ID data field.
See also: Customizing Traffic Lights |
DI027481 Action ID
Here, the ID of the objects which are addressed when carrying out an action is entered.
Details
- A listbox which offers frequently used macros as well as modules which were changed within the last 30 days for selection is implemented on this field.
Actions can be defined for data fields with the following DF behavior:
- c2, c4, c5
- d2, d4, d5
- e2, e4, e5
- f2, f4, f5
- g2, g4, g5
- m4, m5
DI010190 Action
Name of the module, menu item, or macro entered in the Action ID field which is addressed when an action is carried out
Details
- In the module, this name is used for buttons as well as in the context menu. It can be overwritten by making a deviating entry in the DF heading field.
DI000111 LBMOD
Here, the ID of the listbox module is stored if you have selected DF behavior = "li"/"le" for the data field.
Note
- A listbox which offers the modules that have been changed within the last 30 days for selection is implemented on the parameters. It may, e.g., serve as input help if new listbox modules have recently been created which are to be stored as a listbox.
DI009468 @L variable
- Number of the list variables to be referenced The program saves the data field values of marked records in the entered list variable.
- In the target module, @L must be entered for a data field in Filter from
- Here, a menu item which is to be overwritten is entered for the Overwrite menu items action.
DI000288 Summarization type
Summarization type of the data fields
Values
- 0: No summarization (for DFs "Summarization type" from DI)
- 1: Sum
- 2: Maximum
- 3: Minimum
- 4: Average
- 5: never summarize, always calculate
Notes
- If no value is entered here, the value in the Summarization type parameter of the data item (DT412) applies to the target module.
- If the value entered here deviates from that of the DI, the value of the DF overwrides the value of the DI.
- Summarization type = 5 on a data item (DT412) prevents any summarization and does not allow deviating summarization types in the data field (DT411). For fields with relative values, e.g. percentage specifications, summarization does not make sense. The Never summarize, always calculate summarization type on the data item provides the customizer with a means to prohibit this effectively.
- If a summarization type is neither stored on the Summarization type parameter of the data field (DT411) nor on the parameter of the same name of the data item (DT412), the following default summarization type is used:
- Alphanumeric: Maximum
- Numeric: Sum
- Date fields: Maximum
- The values of the checkbox fields are not summarized, the checkboxes are always displayed as deactivated
- Due to the rounding of individual fields, an incorrect sum may be displayed since it is calculated from the exact values and displayed rounded afterwards due to formatting.
DI001706 Grid
Values
- For histogram data fields:
- The grid specifies the scale graduations of the histogram scale.
- Example: When Grid = 100, the y axis of the scale is divided into steps of hundreds (100, 200, 300, etc.).
- For time scale data fields (division of the x axis of the time scale):
- 2: day
- 3: week
- 4: month
- 5: quarter
- 6: year:
Note
DI040119 LB: Value transfer
This parameter determines which data field from the listbox is transferred.
Values
- : The data field is copied from the listbox.
- : The data field is not copied.
Notes
- You have to make sure that this parameter is used reasonably.
- I.e., for listboxes on project ID fields, the LB: Value transfer parameter should be activated for the project ID, not for the name.
- If this parameter is not activated for any data field in a listbox, nothing from the list can be copied.
- The parameter can only be activated for one data field in the data area. If it is activated additionally for another data field, the activation will be deleted for the first data field.
- If this parameter is activated, the LB: partial string search field.
See also: Customize Listbox, General Information about Listboxes, Listbox section in the Module Workflow Level 1 |
DI040815 LB: Partial string search
This parameter defines for the listbox modules which data fields are considered in the partial string input.
Values
- : The data field is considered in the partial string search.
- : The data field is not considered in the partial string search.
Details
- If the LB: Value transfer parameter is activated for a data field, this parameter is activated automatically. However, it can be deactivated manually.
- In a listbox module you can also set multiple fields or no field at all for the substring search.
Example
- This way you cannot only input the table in the listbox of the DT data field in the Data Dictionary, but also the beginning of the table name in order to filter the LB contents.
Note
- If a listbox contains the value to be copied, a respective name, and an additional detailed description, it is recommended to only use value and name in the partial string search. Including the explanation in the body text will probably produce too many unwanted hits.
See also: Customize Listbox. Use Listboxes |
DI040118 Input only via listbox
If this parameter is activated, data field input is restricted to values from the listbox.
Values
- : Data field input is restricted to values from the listbox.
- : Data field input is not restricted.
Note
- If a value which is not contained in the listbox is entered in a listbox data field manually or via Drag&Drop, the input is ignored and the field remains empty. The user must repeat the input or select a valid value from the listbox.
See also: Customize Listbox |
DI001995 Window
Specifies in which subwindow of a module the data field is displayed. The following partition description applies to PLANTA standard. In individual solutions, the data can be divided differently according to customer requirements.
Details
- Window 1: left-hand data window
- Identifying data (e.g. IDs and names)
- Window 2: central data window
- Other data (e.g. dates and durations)
- Window 3: right-hand data window
- Scale fields and items displayed below a scale (e.g. bars).
- Window 9: hidden data window
- Fields that are hidden when starting the module but can be unhidden by the user. They have the DF options checkbox activated.
- Fields that are hidden in the module and cannot be unhidden by the user, but that are visible in the filter criteria. They have the Filter criteria checkbox activated and the DF options checkbox deactivated.
- Fields that are completely invisible for users. They can neither be unhidden by the user, nor be viewed in the filter criteria. Both the DF options and Filter criteria checkboxes are deactivated.
Notes
- A user can unhide invisible fields, i.e. the fields that are positioned in customizing in window 9, in the corresponding modules by clicking on any fixed data field heading and activating the required fields in the opened context menu. This moves them from the invisible window 9 to one of the visible windows and positions them next to the field from which the context menu was opened.
- If a customizer sets a data field in a data area to window 9 and thus moves the field to the invisible window, the filter criteria and DF options parameters are automatically deactivated.
If a field is to be displayed in window 2 (or window 3), a value must also be entered in the Width W2 (or Width W3) data field in the Other module parameters module.
DI000221 DF behavior
This parameter is used to define the data field behavior. Depending on the data item of the data field, the listbox on the DF behavior parameter only shows values which are possible for the data field which is currently edited.
Function | Value | See also: | Notes |
---|---|---|---|
Background | a | ||
Action on OLE | a2: Menu item a4: Module/Macro a5: Module subclass | When selecting one of these values, symbol 000984 is automatically entered on the respective data field and the DF height = 40 is allocated to optimize the OLE representation. | |
Password field | b | ||
Bar | ba | ||
Click on the | c2: Menu item c4: Module/Macro c5: Module subclass | Can only be selected with button DI 004336 | |
Date listboxes (for date fields) | cc | ||
Overwrite Menu Item | d2: with menu item d4: with module / with macro | Can only be selected with button DI 004336 | |
Link | e2: Menu item e4: Module/Macro c5: Module subclass | ||
Action when double-clicking | f2: Menu item f4: Module/Macro f5: Module subclass | ||
Action when pressing ENTER | g2: Menu item g4: Module/Macro g5: Module subclass | ||
Hyperlink | h | ||
Hotkey | hk | ||
Hyperlink for output | ho | ||
Input field | i i2: Checkbox - only for Y types | ||
Listboxes | li: implicit le: explicit | ||
Context Menu | m4: Module/Macro m5: Module subclass | Can only be selected with button DI 004336 | |
Mark down | mi: input mo: output | ||
Output field | o o2: Checkbox - only for Y types | ||
IronPython Script | py | Can only be selected with button DI 004336 | |
Browser control data field (web embedded) | we | Can only be selected with button DI 004336 | |
Adaptive Card Designer data field | ad | Can only be selected with button DI 004336 | |
Application Link data field | al | Can only be selected with button DI 004336 | |
Chart data field | ch | Can only be selected with button DI 004336 | |
Adaptive Card data field | ac | Can only be selected with button DI 004336 Make the following definition in the Data field configuration:
| |
Adaptive Card Designer data field | ad | Can only be selected with button DI 004336 Make the following definition in the Data field configuration:
The data fields must be in the same data area as the Designer. Via the context menu you can use additional features of the Designer. |
Note
- To open a method with data field behavior *5, it must have the following signature:
def my_method(self, applied_dfc, clicked_df):
pass
DI002926 Mandatory
Here you can define whether a data field is a mandatory data field.
Values
- : The data field is a mandatory data field. When creating or changing a record, an entry must be made in this data field. Otherwise, the change cannot be saved.
- : The data field is not a mandatory data field.
Details
- The Mandatory function can be used on all fields that do not accept an empty value or zero since blank spaces or zero are not considered as entry.
- It is not reasonable to use this function for checkbox fields since here, a check is only performed when the checkbox is activated.
- Ident data fields do not need to be set to Mandatory, these are automatically mandatory entries so that the data record is valid according to the database rules.
- For date data fields, the mandatory function has no effect. Saving is also possible when there are empty data fields. However, it can be queried via another DI.
Note
- For mandatory data fields, an * is displayed automatically behind the heading.
DI000223 Default value
Here, you can enter the value with which the respective data field is filled by default during the creation of a record. Here, the data area must be set to Create = .
Details
- If the required data field is contained in a subordinate area which is set to Create = , but is to be filled with a default value when creating a parent data area, the data field must additionally be included in the creation area with its default value and possibly be set to Window = 9.
Special values
- @/@D/@G/@U: the value of a variable (e.g. today's date or resource) is entered.
DI000220 Sort order
Here, the number is entered/displayed which specifies in which order it is sorted by this field within the respective data area. A minus sign means sorting in descending order (e.g. -1): If no sort order is defined for any of the fields, the respective data area will be sorted by the DDI of the data area.
Details
- The sort criteria take effect when carrying out a search or when clicking on the Data→ Sort menu item.
For a description of the menu items, see here.
- Sorting only takes effect within a data area.
- It must be specified consecutively.
DI001714 Filter from
Here you can set filter criteria by which the data of a module is filtered. Absolute values or variables can be entered.
Details
- The field can be preset by the customizer. In this case, the data is filtered when the module is opened.
- Or the user can fill the field himself/herself with the required value in the Filter Criteria module. In such a case, the data is filtered after clicking on the Filter or Filter additively button.
Notes
- For virtual data fields, the value in this field is marked red and bold.
- If no filter criteria have been preset, all data will be found when filtering.
- If you often filter on the same data field, it is advisable to set a respective index in the database.
DI001718 Filter to
For description, see Filter from
DI040816 Regular expression
In this field, regular expressions for filtering are stored.
Note
- Filters with regular expressions can only be used for alphanumeric fields.
See also: Regular Expressions |
DI056857 Use filter for
Values
- 0: everywhere
- For structures, the filter is used at every level.
- 1: only at the top level
- Filter only takes effect at the highest level (only usable for structures)
- 2: not at the top level
- Filter does not take effect at the highest level (only usable for structures)
Example
- The IT-ST resource has child resources R48 and R9.
- In the Resource Structure module, only the IT-ST resource and the parent external resource are to be displayed (here R9).
- For this purpose, make the following settings in the data area:
- Filter from = IT-ST and Use filter on = 1 for the Resource (Resource ID) data field.
- Filter from = 1E and Use filter on = 2 for the Resource type data field.
- Result: After opening the module, only the IT-ST resource and child resource R9 are displayed.
DI056858 Filter deactivated
If this parameter is activated, all entries in the Filter from, Filter to, Regular expression, and Use filter on parameters of the respective data item are ignored when filtering. For clarity, these 4 fields are grayed out.
DI000234 Symbol ID
ID of the symbol which is to apply to the data field.
Notes
- The value defined here
- overrides the possible symbol definition at data item level (Symbol ID in DT412) and at skill level (Input field symbol, Output field symbol and Hyperlink symbol in DT030).
- is overridden if a traffic light is assigned to the data field.
Details
- For the data field heading, the symbol defined in the Hdg symbol ID parameter applies.
See also: Create, Edit, Delete Symbols |
DI002031 Symbol
Preview of the data field symbol which is defined via the Symbol ID parameter
DI010197 Hdg symbol ID
ID of the symbol of the data field heading
Note
- If a symbol for the data field heading is entered at data field level, it overrides a possibly existing deviating heading symbol at skin level (Heading symbol in DT030).
See also: Create, Edit, Delete Symbols |
DI010201 Hdg symbol
Preview of the data field symbol which is defined via the Hdg symbol ID parameter
DI029731 Effect ID
ID of the data field effect
Notes
- The effect affects the entire field content (font and background).
See also: Create, Edit, Delete Effects |
DI000258 Format ID
Here, the ID of a date or number or currency format for a data field is entered/displayed.
Note
- The format specified here overrides deviating formats for the corresponding data field which are possibly specified at other levels:
- at skin level: the formats specified in the Date format, Currency format, or Number format parameters
- at user level: the formats specified in the Date format, Currency format, or Number format parameters
- on data item level: the format specified in the Format ID parameter
See also: Create, Edit, Delete Formats |
DI002076 Format
Here, a preview of the format which has been specified for the selected data field in the Format ID parameter is displayed.
DI003701 DF height
Here, the height of the data field in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
DI003703 DF width
Here, the width of the data field in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
Notes
- If the heading or the value of the data field cannot be displayed in the set width at the surface of the respective module, the data will be truncated and displayed with an ellipsis.
- If the cursor hovers over the truncated data, the complete data is displayed in a tooltip.
DI027098 Hdg height
Here, the height of the data field heading in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
DI027099 Hdg width
Here, the width of the data field heading in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
DI000232 Y Pos. H
Here, the Y position of the data field heading in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
Notes
- This parameter only takes effect in data areas with Layout = 2 (form).
- Data field headings cannot be displayed in the module without the corresponding data fields.
DI000233 X pos. H
Here, the X position of the data field heading in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
Notes
- This parameter only takes effect in data areas with Layout = 2 (form).
- Data field headings cannot be displayed in the module without the corresponding data fields.
DI000230 Y pos. F
Here, the Y position of the data field in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
Notes
- This parameter only takes effect in data areas with Layout = 2 (form).
- Data fields can be displayed in the module without the corresponding data field headings.
DI000231 X pos. F
Here, the X position of the data field in the selected data area is displayed/defined.
Values
- Specified in tenths of a millimeter.
Notes
- This parameter only takes effect in data areas with Layout = 2 (form).
- Data fields can be displayed in the module without the corresponding data field headings.
DI022738 Alignment
Determines the alignment of the data field.
Values
- 0: no alignment
- 1: left aligned
- 2: centered
- 3: right aligned
Notes
- Checkboxes are always centered, regardless of the alignment.
- Number fields are right-aligned and text fields are left-aligned by default.
DI001992 Pos.
Automatically incrementing position number. When moving via Drag&Drop moving and creating a data field, the pos. is set automatically. In modules in which data fields are created, this field should be the first sorting criterion in window 9.
Note
- The position is the tab order of the data fields at the same time.
DI040869 Hotkey
The entered value defines a shortcut for activating the corresponding button.
Example:
- Value: A
- In the module, the respective button can be activated via the ALT + A key combination.
DI040918 Tooltip
Here you can store a fixed tooltip. It will be displayed when the cursor hovers over the corresponding field in the target module.
The following variables can be used:
Field Type | Variables | Notes/examples |
---|---|---|
Regular data fields | @uid - DF ID of the data fields @content - Content of the data field is displayed. | |
Bar | @startDateH(date format) - start date of the bar is output @endDateH(date format) - end date of the bar is output @duration - number of days between start and end date is output. @wdDuration - number of days between start and end date, excluding weekends and holidays, is output @ds, @de - start date/end date @ms, @me - start month/end month @qs, @qe - start quarter/end quarter @ws, @we - start week/end week @ys, @ye - start year/end year of the histogram bar @wys and @wye - start year/end year of the calendar week | Note:
|
Histograms | @value - value of the histogram bar on which the cursor is placed (e.g. bars for projects with code B) @v_sum - sum of the values for the bars of a group (of a type) (e.g. bars for projects A-E) @hdg - name of the histogram (=DI name of the SUBDI) @ds, @de - start day/end day @ms, @me - start month/end month @qs, @qe - start quarter / end quarter @ws, @we - start week/end week @ys, @ye - start year/end year of the histogram bar @wys and @wye - start year/end year of the calendar week |
Example
Entry in the customizer | Output at the surface | |
---|---|---|
Start: @startDateH(dd.MM.yy) End: @endDateH(dd.MM.yy) Duration: @wdDuration days | Start: 07/01/2009 End: 07/15/2009 Duration: 10 days |
Information
- The field is an I-text field, which means that the tooltip texts stored here can be translated in the translation modules.
DI003388 DF options
This parameter serves to determine whether data fields in the context menu for hiding/unhiding of data fields can be hidden/unhidden.
Values
- : The data field can be unhidden/hidden.
- : This data field cannot be unhidden/hidden.
Note
- If a field in a data area is moved to an invisible window (window 9), the DF options parameter is deactivated automatically.
DI059179 Bar modification mode: Create bar
Activating this checkbox enables the graphical creation of the bar. It is recommended to only set one date type to "create" (e.g. actual dates or requested dates).
DI059181 Bar modification mode: Edit dates: MI "Actual"
Activating this checkbox enables the
- graphical editing of dates of the respective bar with Edit → Task actual start and Edit → Task actual end.
- scrolling to actual dates via the View → Bar tracking menu items.
DI059180 Bar modification mode: Edit dates: MI "Requested"
Activating this checkbox enables the
- graphical editing of dates of the respective bar with Edit → Task requested start and Edit → Task requested end.
- scrolling to requested dates via the View → Bar tracking menu items.
DI059186 Bar modification: Link Bar
Activating this checkbox enables you to graphically link the bar, change the link type by right-clicking, and graphically delete the link in the Gantt chart. For this purpose, see Edit Gantt Chart in the PLANTA project/portfolio help area.
Requirements
- In the link area, a Linkage DI is available for the bar you wish to link.
DI059183 Bar modification: Edit Start
Activating this checkbox enables the graphical editing of the start dates
DI059184 Bar modification: Edit End
Activating this checkbox enables the graphical editing of the end dates
DI059268 Bar modification: Move
Activating this checkbox enables the graphical moving of the bar
DI059185 Bar modification: All modifiable
Activating this checkbox enables the graphical moving of the bar as well as the editing of the start and end dates
Note
- When activating this checkbox, the following checkboxes are activated automatically
DI051832 Bar link (DF Python ID)
By entering the DF Python ID of a bar, this data field becomes an auxiliary bar field. It is displayed at the position defined in the Docking point parameter.
Note
- The auxiliary bar field must be located in the same field as the respective bar.
DI040921 Bar link (DF ID)
By entering the DF ID of a bar, this data field becomes an auxiliary bar field. It is displayed at the position defined in the Docking point parameter.
Note
- The auxiliary bar field must be located in the same field as the respective bar.
DI040917 Dock point
This parameter serves to determine the position of the auxiliary bar field defined in the Bar link (DF Python ID) data field.
Values
- 0: starting point is bar start
- 1: starting point is bar end
- 2: starting point is bar center
Tip
- When you use "0” as a value for positioning an auxiliary field infront of the bar, the data field width and the X position of the field should be defined in addition (e.g. DF width = 200, X pos. F = -200), so that the field is not positioned at the bar itself.
DI026689 Multiline
This parameter controls whether line breaks are possible in the respective data field.
Values
- : By pressing enter, a line break is inserted. If the DF width is reached, an automatic line break occurs.
- : By pressing ENTER you navigate to the next input field. If the DF width is reached, the data is displayed truncated with an ellipsis. If the cursor hovers over the truncated data, the complete data is displayed in a tooltip.
DI027601 No. of lines
For data fields for which the Multiline parameter is activated, you can use this parameter to define how many lines may be written in this data field. If the maximum number of lines is reached, no other manual line breaks or no other text can be entered if this causes an automatic line break. In such a case, the The maximum amount of lines in the continuous text field has been reached. message is displayed.
Notes
- Values from 0 to 9999 can be entered.
- The parameter is hidden by default in the Data Area module and can be unhidden from the invisible window.
DI001993 Filter criteria
This parameter defines whether the data field is displayed in the Filter Criteria.
Values
- : The data field exists as a filter criterion in the option form.
- : The data field does not exist as a filter criterion in the option form. However, an entry in the Filter from or Filter to takes effect regardless.
Notes
- If a field in a data area is moved to an invisible window (window 9), the Filter criteria parameter is deactivated automatically.
- Can be used for filter criteria which the user can neither see nor change.
- Can be used for data fields which cannot be searched for, e.g.: Date, histogram bars, projection values, summarized values.
- Especially in multi-user mode, large sequential search runs can cause computer overload. It is therefore recommended, especially where bulk data is involved, to limit the filter criteria which are visible to the user.
DI029687 DF output
Preview of the data field heading as it is displayed in the module.
DI003102 DF type
The field is automatically filled with the value from the (DF type) field of DT412.
DI040844 Incarnation DI
The field is automatically filled with the value from the (Incarnation DI) field of DT412.
DI040843 Fetch exit DI
The field is automatically filled with the value from the (Fetch exit DI) field of DT412.
DI040845 DI class
Here, the class of the hyperlink is displayed.
DI041524 Listbox module
Here, the title of the listbox module stored in the LBMOD data field is displayed.
DI041308 DBOLE value
Here, the ID of the OLE object is displayed which is used on the data field. The field is automatically filled as soon as an OLE entry has been made in the Default value field. For more information, please refer to the Embed OLEs section of Module Workflow Level 1.
DI040904 IronPython script
On this parameter you can store IronPython scripts that are carried out on the client. This allows you to customize a sort of value range on the part of the client.
Notes
- In order to run !IronPython scripts on the client, the DF behavior must be set to py.
DI040968 Data field configuration
On this parameter you can store configuration parameters for data fields.
Usage
- For IronPython and Python scripts, e.g. for changing person/resource IDs
- For storing the IDs of the tooltip modules
- For the parameter settings of the date listboxes (calendar listboxes) with calendar control function
- For client specific data field configuration
Parameters that are used on the part of the client can be declared.
CODE#START DF client config. chart_usage=True #END
For configuring the Adaptive Card data fields
- For configuring the context menu button
- For storing a tooltip module
- To store a tooltip module you can also use the data item configuration if the tooltip module is to be displayed in all modules in which the respective data item is used. If deviating tooltip modules are entered in both parameters, the entry in the data field configuration overrides the entry in the data item configuration.
{
"Tooltip": {
"Module": "xxxxxx"
}
}
DI056920 Print text
Here, an individual print output text or variables for print output objects can be defined for a print area.
Possible variables:
- @mod_name - module name
- @cur_column - current column
- @cur_row - current row
- @cur_page_h - current page (horizontal counting)
- 1,2,3
- 4,5,6
- @cur_page_v - current page (vertical counting)
- 1,3,5
- 2,4,6
- @total_pages - page number
- @date_time(F) - time specific for the print preview
- @date_time(h:mm:ss) - time specification
- @date_time(dd.MM.yy HH:mm:ss) - time for the print preview
- In these variables, only standard format strings can be used. For further information, please see here.
DI041307 DBOLE
Preview of the OLE object which was assigned to the data field.
DI000106 Structure summarization
Summarizes data fields in data areas with Structure display = along the structure (e.g. planned load along the project structure)
DI062619 Active
Marks the data field as active or inactive, depending on whether the respective data item is active or inactive.
Note
- If you try to assign an inactive data item to a data area as a data field, a message indicating this is displayed.
DI066279 Active chart variant
Defines which chart variant is to be displayed if there are multiple chart configurations for a data field.
The parameter can be edited in the following module by users with modification rights: